Detector AW-CSD311
Operating Voltage Range
9 to 28 VDC Volts Non-polarized
Standby Current
≤120A@24VDC
Maximum Alarm Current (LED on)
≤15mA@24VDC(K Ohm current-limiting resistance)
Fix temperature Alarm
570C (1350F) A1R
DETECTOR AW-CSD381
Operating Voltage Range:
9 to 28 VDC Non-polarized
Standby Current:
≤120uA@24VDC
Maximum Alarm Current(LED on):
≤15mA@24VDC
(1K Ohm current-limiting resistance)
Operating Humidity Range:
≤95%RH(40℃±2℃)RelativeHumidity,
Non-condensing
Detector AW-CSD812
Operating Voltage Range
9 to 28 VDC Volts Non-polarized
Standby Current
≤120uA@24VDC
Maximum Alarm Current (LED on)
≤20mA@24VDC
(1K Ohm current-limiting resistance)
Detector AW-CTD382
Operating Voltage Range
9 to 28 VDC Volts Non-polarized
Standby Current
≤120uA@24VDC
Maximum Alarm Current (LED on)
Detector AW-CTD321
Operating Voltage Range
9 to 28 VDC Volts Non-polarized
Standby Current
≤120 A@24VDC
Maximum Alarm Current (LED on)
≤20mA@24VDC (1K Ohm current-limiting resistance)
Fix temperature Alarm
570C (1350F) A1R
Detector AW-CTD322
Operating Voltage Range:
9 to 28 VDC Volts Non-polarized
Maximum Alarm Current(LED on):
≤48mA@24VDC
Operating Temperature Range:
-10℃ to 70℃
Detector AW-CSH831
Operating Voltage Range
9 to 28 VDC Volts Non-polarized
Standby Current
≤120μ A@24VDC
Maximum Alarm Current (LED on)
≤15mA@24VDC
(1K Ohm current-limiting resistance)
Detector AW-SST606D
Working power:
A CR17335/17450 lithium manganese battery B 2* AA alkaline battery
Current: ≤8µA@3VDC
Maximum Alarm Current (LED on):
≤100mA@3VDC
Conventional Panel AW-CFP2166-1
AC INPUT
220VAC 50/60Hz
+10%
-15%
DC OUTPUT
24VDC typical
Voltage for MCU
5V
Current @ 220VAC
standby current ≤250mA
Maximum current
1A
Batteries current
750mA maximum, current limited
Batteries
2*12V/ 2.3Ah sealed lead acid gel, self-regulated
Battery low-voltage protection
22.2V
Conventional Panel AW-CFP2166-2C
AC INPUT
220VAC 50HZ
+10%
-15%
DC OUTPUT
24VDC typical
Voltage for MCU
5V for power board MCU, 3.3V for others
Current at 24VDC from PSE
450mA standby current
Maximum current from PSE
2A except batteries charge
Batteries current
1.85A maximum, current limited
Auxiliary output
24VDC +/- 10%, 100 mA max,
current limited, monitored
Conventional Panel AW-CFP2166-4
AC INPUT
220VAC 50HZ
+10%
-15%
DC OUTPUT
24VDC typical
Voltage for MCU
5V for power board MCU, 3.3V for others
Current at 24VDC from PSE
450mA standby current
Maximum current from PSE
2A except batteries charge
Batteries current
1.85A maximum, current limited
Auxiliary output
24VDC +/- 10%, 100 mA max,
current limited, monitored
Conventional Panel AW-CFP266-6C
6 Zone Fire alarm control Panel
Model No.
AW-CFP2166-04-16
Mains supply voltage
110VAC or 240VAC
Internal power supply
27.2VDC
Total output current limited
3A @ 240VAC
Batteries (Default Configuration)
12V2AH*2-24VDC in Total
Conventional Panel AW-CFP2166-8C
8 Zone Fire alarm control Panel
Model No.
AW-CFP2166-04-16
Mains supply voltage
110VAC or 240VAC
Internal power supply
27.2VDC
Total output current limited
3A @ 240VAC
Batteries (Default Configuration)
12V2AH*2-24VDC in Total
Conventional Panel AW-CFP2166-12-32 Zone
12-32 Zone panel
Model No.
AW-CFP2166-12-32
Mains supply voltage
110VAC or 240VAC
Internal power supply
27.2VDC
Total output current limited
3A@240VAC
Batteries (Default Configuration)
12V2AH*2-24VDC in Total
Conventional Manual Call Pont AW-135-C
AW-D135C
Main Voltage
Zone 24V or 12V
Operating current
monitoring status≤20uA, alarm status≤15mA
Application
For indoor use only
Wiring
The promise of two bus system(Zone +, Zone -)
Indicator
Red alarm indicator flashes when it is under normal condition,
press the manual button lit work
Conventional Push Station AW-CMC2166-6
Working Voltage
24VDC
Work Current
≤40uA @24VDC
Alarm Current
≤50mA @24VDC
Contact Resistance
≤0.02 ohm
Conventional Fire Bell AW-CBL2166-6
Working voltage
20VDC to 28VDC
20VDC to 28VDC
Work current @24VDC
≤50mA
≤50mA
Volume(dB) @1m
≥98dB
≥100dB
Dimensions
150mm*150mm*60mm
200mm*200mm*67.5mm
Conventional Strobe Sounder AW-CSS-2166-2
AW-CSS2166-2
Operating Voltage
Zone 24V
Operating current
≤60mA
Alarm SPL
≥85dB
Flash Period
1 Time/Sec
Environmental
Temperature range: -5 to 40°C (23~104°F)
Humidity: 5 to 95% RH, non-condensing
Conventional Sounder Beacon AW-D316Model No. : AW-D316
Transmission Mode ` : Cable
Alarm Volume (within 1m) : ≥80dB
Product Nam : Fire Alarm Horn Strobe
Flash Color and Frequency : White, 0.5Hz
Operating Voltage : 24VDC (20V~28V)
Conventional Flash Light AWCFL2166
Operating Voltage
DC24V
Flash Period
≤3s
Temperature Range
-10℃ ~ +50℃
Humidity Range
0%~95%RH
Beam Detector 100meters AW-BK901
Standard Compliance
EN54-12
Fire Detection and Alarm Systems
BS 5839 Part 1:2002
Operating Voltage
20 V to 28 V DC
Entrance LED Indicator AW-EL102
Working voltage: 220VAC/50Hz or 24VDC
Maximum current:5A (220VAC/50Hz) or 8A(24VDC)
Contactor resistance: ≤0.1Ω
2-wire system
Compatible with all the conventional fire alarm control panel
Beam Smoke Detector Programmer AW-BK901
Addressable Panel AW-FP101-108 1LOOP-8LOOP
Detectors
500MAX
Work Voltage
220V AC
Battery
12V/5Ah*2
24V DC Output Current
Max 3A*2
Frequency
50/60Hz
Work temperature
-10~55℃
Work Humidity
95%
Certificate
ISO9001/ROHS
Battery 12V5AH AW-B12052 (1-2LOOPS)2pcs lead acid batteries ,for 1-2 loop panel, standby 8 hours
Detector Addressable AW-D101
Operating Voltage Range
18V-28VDC
Alarm Current
≤3mA
Work Current
≤2.5mA
Temperature
-10℃ to 50℃
Smoke Sensitivity
0.1-0.15 dB/m
Standard Number Ref
EN 57-7:2000
Size
99.80mm
Detector Addressable AW-D102
Operating Voltage Range
18V-28VDC
Alarm Current
≤3mA
Work Current
≤2.5mA
Temperature
-10℃ to 50℃
Fix Temperature Range
57℃ A2R
Rate of Rise Alarm
7.1℃/5S A2R
Standard Number Ref
EN 54-5:2000
Size
99.80 mm
Detector Addressable AW-103
Operating Voltage Range
18V-28V DC
Alarm Current
≤3mA
Work Current
≤2.5mA
Temperature
-10℃ to 50℃
Smoke Sensitivity
0.1-0.15dB/m
Fix Temperature Range
57℃ A2R
Rate of Rise Alarm
7.1℃/5S
Standard Number Ref
EN 54-5:2000
Size
99.80mm
Addressable Manual CallPoint AW-D105
Work Voltage
18V-28V DC
Work Current
≤4mA
Protection Level
IP 30
Terminals Connection
Loop In±
Loop Out±
Addressable Strobe Sounder AW-D106
Operating Voltage
18V-28V DC
Work Current
10-60 mA
Standby Current
≤3 mA
Alarm SPL
≥100dB
Flash Period
≤1.0 S
Temperature
-10℃~50℃
Detector Wireless AW-SSD606A
A CR17335/17450 lithium manganese battery B 2* AA alkaline battery
Current:
≤8µA@3VDC
Maximum Alarm Current (LED on):
≤100mA@3VDC
Operating Humidity Range:
≤95%RH(40°C±2°C)
Operating Temperature Range:
-10°C to 50°C (14°F to 122°F)
Smoke Alarm Sensitivity:
0.18-0.26dBM
Alarm level:
≥85db /3m
Addressable Panel (LPCB)AW-FP300
230VAC (-15%, +10%). 47 ~ 63Hz. Max current 0.8A
Mains fuse
T3.15AL250V
Operating voltage
18.5 ~ 30VDC
Recommended mains cable
Screened or standard/black mains cable, cable size 0.75mm2
Power rating
Imax.a=1.2A; Imax.b=2.6A; Imin=0.65A
Max. charging current
1.2A
Max. battery supply current
4A (when the Mains is disconnected)
Detector(LPCB)AW-D301
Operating Voltage
Loop 24V(18V~28V)
Standby Current
<0.3mA
Alarm Current
<1.5mA (without remote indicator)
<3.5mA (with remote indicator)
Fire LED
Red, Flash in polling, and illuminate in alarming.
Remote indicator output
Polarity-sensitive output, directly connect to remote indicator (built in 10k
resistor in series, max. output current is 2mA); The red indicator will blink in the monitoring status or remain lit in the alarm status.
Detector(LPCB)AW-D302
Operating Voltage
Loop 24V(18V~28V)
Standby Current
<0.3mA
Alarm Current
<1.5mA (without remote indicator)
<3.5mA (with remote indicator)
Class
A2
Fire LED
Red, Flash in polling, and illuminate in alarming.
Remote indicator output
Polarity-sensitive output, directly connect to remote indicator (built in 10k resistor in series, max. output current is 2mA); The red indicator will blink in
the monitoring status or remain lit in the alarm status.
Detector(LPCB)AW-D303
Operating Voltage : 24V
Standby Current : <0.3mA
Alarm Current : <1.5mA (Without Remote Indicator)
Wiring : Two Wire, Polarity-Insensitive
Manual Call Point(LPCB)AW-D305
Operating Voltage
Signal Loop 24V(18V~28V)
Power 24VDC(20VDC~28VDC)
Standby Current
Loop<0.8mA ; Power<2mA
Action Current
Loop<5mA ; Power<15mA
Output Capacity
1A@DC30V
Input Mode Setting
NC or NO input mode can be set by the jumper JP4.
Programming Method
Electronically addressed
Code Range
One address within 1~324.
Sounder Beacon(LPCB)AW-D306
op input
DC24V(18-28V),≤1mA(monitoring status),≤3mA(alarm status)
Power input
DC24V(20-28V),≤4mA(monitoring status),≤130mA(alarm status)
Power consumption
≤3.2W@DC24V
EN54-23 Coverage
C-3-8/W-2.4-6(coverage volume see the following figures)
Flash Color and
Frequency
White, 0.5Hz
Light Output
Synchronization
Meets EN54-23
Addressable Fire Bell AW-D109
Work Voltage
18V-28V DC
Standby Current
≤3 mA
Alarm Current
≤50 mA
Certificate
ISO9001/CE/ROHS
Size
110 mm×110 mm
Addressable Monitor Module AW-D110
Operating Voltage
18V-28V DC
Standby Current
≤ 5mA
Alarm Current
≤ 25mA
Temperature
-10℃~50℃
Addressable Supervisory Module AW-D111
Operating Voltage
18V-28V DC
Standby Current
≤ 5mA
AUX Output
≤200 mA @24 VDC
Temperature
-10℃~50℃
Addressable Control Module AW-D112
Operating Voltage
18V-28V DC
Load Capacity
≤ 200 mA
Standby Current
≤ 5mA
Temperature
-10℃~50℃
Addressable Relay Module AW-D113
Operating Voltage
18V-28V DC
Standby Current
≤ 3mA
Alarm Current
≤ 30mA
Relay Capacity
2A@ 24VDC &
1A@ 25VAC
Protection Level
IP 30
Temperature
-10℃~50℃
Isolator Module AW-D114
Standby Current
≤ 25 mA
Alarm Current
≤ 80 mA
Output Current
≤900mA
Protection Level
IP 30
Temperature
-10℃~50℃
Addressable Annunciator AW-D116
Operating Voltage
18V-28V DC
Work Current
10-30mA
Temperature
-10℃~50℃
Addressable Annunciator Board AW-D117/D118
Operating Voltage
18V-28V DC
Work Current
10-30mA
Temperature
-10℃~50℃
Addressable Sounder Base AW-D120
18~28VDC
Warranty:
2 Years
Standby Current:
≤3mA
Alarm Current:
≤60mA
Work Temperature::
-10℃~50℃
Addressable Power Transmitter AW-D121
Programmer AW-PR101
Loop Isolator (LPCB) AW-D314
24V
Standby Current
<3mA
Capacity
32 devices
Indicate
Yellow (flashes when polling, illuminates in action.)
Maximum Line Voltage ( VMAX)
28V
Addressable LPG Detector AW-D315 Two Wire, Polarity Insensitive
Programming : Electronically Addressed
Alarm Current : <1.5mA (Without Remote Indicator)
Standby Current : <0.3mA
Model No. : AW-D315
Conventional Sounder Beacon(LPCB)AW-D316
Operating Voltage
Power: 24VDC (20V~28V)
Operating Current
≤100mA
EN54-23 Coverage
C-3-8/W-2.4-6(coverage volume see the following figures)
Flash Color and Frequency
White, 0.5Hz
Light Output Synchronization
Meets EN54-23
Addressable Input/Output Module AW-D319
Operating Voltage
Signal Loop 24V(18V~28V)
Power 24VDC(20VDC~28VDC)
Standby Current
Loop<0.8mA ; Power<2mA
Action Current
Loop<5mA ; Power<15mA
Output Capacity
1A@DC30V
Input Mode Setting
NC or NO input mode can be set by the jumper JP4.
Reapeter AW-RP2188
Executive standard
General Technical Conditions for Fire Indicating Panels (GB17429-1998)
Display capacity
Each display panel can display the fire alarm messages of floors -10~90 and at most 99 fire alarm messages or feedback messages.
Wiring system
Four-wire system, power lines (+24V, GND) and RS485 signal lines (485A, 485B)
Programmer AW-CODER2188 1600mAh lithium battery;
External 24V/500mA DC can be used as direct work power supply or to charge the battery;
Working current: 15mA—170mA, standby current: 15mA;
Ambient temperature: -20℃~60℃, relative humidity: 5%~95%.
Graphic Monitoring Computer AW-AW-CRT9000
CPU
Basic frequency 1.5G or above
Memory
Above 256m
Mainboard
With PCI slot
Hard disk
80G or above
Graphic card
16K color, above 800*600
Addressable Fire Telephone Panel AW-FT599
Power supply
Mains power: AC 220V (+10%, -15%, 50Hz)
Standby power supply: External DC24V
Bus current
≤600mA
Frequency range
300~3400Hz
Addressable Fire Telephone Jack AW-D501
Power supply
Mains power: AC 220V (+10%, -15%, 50Hz)
Standby power supply: External DC24V
Bus current
≤600mA
Frequency range
300~3400Hz
Transmission attenuation
≤5dB
Recording duration
more than 20min
Conventional Fire Telephone Handset AW-D502
Operating Voltage
AC220V 50HZ or DC24V
Alarm Current
≤0.5A
Temperature Range
-10 ºC ~ +40ºC
Other Details
Frenquency Range: 300-3400Hz(±3dB)
Cross talk Level: ≤-60dB
Sending Allowance: ≤5dB
Conventional Fire Telephone Jack AW-D504
Power supply
Mains power: AC 220V (+10%, -15%, 50Hz)
Standby power supply: External DC24V
Bus current
≤600mA
Frequency range
300~3400Hz
Transmission attenuation
≤5dB
Recording duration
more than 20min
Length of bus
≤1,500m
Addressable Fire Telephone Handset AW-D505
Fire Telephone Handsets Aw-Fhs101
Power Supply:
AC 220V 50Hz or DC 24V
Extension Loop Resistance:
Not More Than 1000 Europe
Frequency Range:
300 ~ 3400Hz (± 3 dB)
Crosstalk Level:
Less Than -60dB (600 Ohm Load
Voice Evacuation Control Panel AW-VP350
Panel Name:
Voice Evacuation Control Panel
Model No.:
AW-VP350
Power supply
AC 220V (+10%,-15%, 50Hz)
Remote control trigger mode:
24VDC
Small Ceiling Speaker AW-SPO1
Diameter:180mm
Thickness: 60mm
Ceiling hole::147 mm
Power:3-6W
Voltage: 70/110V
Frequency response:100-16kHz
Sensitivity:90dB
Big Ceiling Speaker AW-SPO2
Diameter:213mm
Thickness: 65mm
Ceiling hole::170 mm
Power:6-10W
Voltage: 70/110V
Frequency response:100-16kHz
Wall Mounted Speaker AW-SP03Size: 260×185×120mm
Power:10-15W
Voltage: 70/110V
Frequency response:100-16kHz
Sensitivity:90dB
Loudest pressure level (1m): 95dB
15W Water Proof Speaker AW-SP04Size: 202*120*234mm
Power:15-30W
Voltage: 70/110V
Frequency response:420-6000Hz
Loudest pressure level (1m): 118dB
Shell material: ABS
Weight: 1.45kg
Color: white
30W Water Proof Speaker AW-SP05Size: 2220*165*240mm
Power:20-30W
Voltage: 70/110V
Frequency response:420-7000Hz
Loudest pressure level (1m): 118dB
Shell material: ABS
Weight: 1.21kg
Color: white
Apollo Fire Detection & Alarm System
BROCHURE
Apollo Smoke Detector 55000-316APO
Power-up surge current
0.115mA
Maximum power-up time
30 seconds
Status indicator - Alarm
Red
Status indicator - Fault
Off
Quiescent current
50μA
Quiescent current tested at
24V dc
Supply voltage (max)
33V dc
Supply voltage (min)
9V dc
Apollo Smoke Detector 55000-216APO
0% to 95% RH (no condensation or icing)
Operating temperature:
-20 to 60°C
Storage temperature:
-30 to 80°C
Weight:
102g
Color:
white
Apollo Heat Detector 55000-126 APO
Humidity (max)
95% RH
Humidity (min)
0% RH
Humidity Note
no condensation or icing
Humidity
0% to 95% (no condensation or icing)
Operating temperature
20 to 90°C
Apollo Detector Base 45681- 200APO
One-way fit
Easy to wire
Contains an earth connector
Contains no electrical parts
Terminal for remote indicator
Apollo Heat Detector 55000- 217APO
Radioactive Isotope Activity: 33.3kBq
Alarm Current (At 24 Volts): 52mA
Holding Voltage (Min): 6V
Minimum Voltage To Light Alarm LED: 12V
Alarm Reset Time: 1s
Apollo Heat Detector 55000-315APO
Power-up surge current
0.115mA
Maximum power-up time
30 seconds
Status indicator - Alarm
Red
Status indicator - Fault
Off
Quiescent current
50μA
Quiescent current tested at
24V dc
Supply voltage (max)
33V dc
Supply voltage (min)
9V dc
Apollo Detector Base 45681-248APO
Operating voltage:
9 - 33 V DC
Operating temperature:
-20°C to 60°C
Storage temperature:
-20°C to 60°C
Approvals:
CPD
LPCB
Apollo Heat Detector 55000-122APO
Polarity
L1 & L2 are polarity insensitive
Holding voltage
6 to 6V
Holding voltage (max)
6V
Holding voltage (min)
6V
Minimum voltage to light alarm LED
12V
Apollo Smoke Detector 55000-317APO
Power-up surge current
0.115mA
Maximum power-up time
30 seconds
Status indicator - Alarm
Red
Status indicator - Fault
Off
Quiescent current
50μA
Quiescent current tested at
24V dc
Supply voltage (max)
33V dc
Apollo Heat Detector 55000-146APO
Humidity (max)
95% RH
Humidity (min)
0% RH
Humidity Note
no condensation or icing
Humidity
0% to 95% (no condensation or icing)
Apollo Detector Base 45681-206APO
One-way fit
Easy to wire
Contains an earth connector
Conventional Manual Call Point 55100-001APO
Humidity (max)
93% RH
Humidity (min)
0% RH
Humidity
0% to 93% (no condensation or icing)
Humidity Note
no condensation or icing
Operating temperature (min)
-10°C
Operating temperature (max)
55°C
Conventional Manual Call POint SC2900-001
Easy access, front reset mechanism Ergonomic reset key (supplied)
EN 54-11 certified
170° viewable LED
Suitable for flush or surface mounting
Manual Call Point- MEDC Style 55000-960APO
Protocol voltage (max)
9V
Protocol voltage (min)
5V
Protocol voltage
5 to 9V peak to peak
Quiescent current
300μA
Quiescent current tested at
24V dc
IS Manual Call Point 55200-940APO
Protocol voltage (max)
9V
Protocol voltage (min)
5V
Protocol voltage
5 to 9V peak to peak
Power-up surge current
1mA
Quiescent current
300μA
Quiescent current tested at
24V dc
Polarity
L1 & L2 are polarity sensitive
Conventional Exd Manual Call Point 29600-508APO
Supply voltage:
250 V ac max., 50 V dc max.
Operating temperature:
-40°C to +55°C
Ingress Protection:
IP66
Weight:
0.8kg
Materials housing:
Marine grade copper-free LM6 aluminium
I.S. Manual Call Point 55100-940APO
Protocol voltage (max)
9V
Protocol voltage (min)
5V
Protocol voltage
5 to 9V peak to peak
Power-up surge current
1mA
Quiescent current
300μA
Quiescent current tested at
24V dc
Polarity
L1 & L2 are polarity sensitive
Manual Call Point (OutDoor) 58100-950APO
Humidity (max)
0% RH
Humidity (min)
95% RH
Operating temperature (min)
-30°C
Operating temperature (max)
70°C
Operating temperature
-30 to 70°C
IP rating
Designed to
Operating temperature
-22 to 158°F
Operating temperature (max)
158°F
Operating temperature (min)
-22°F
Discovery Manual Call Point (Isolating)58100-908APO
Protocol voltage (max)
9V
Protocol voltage (min)
5V
Protocol voltage
5 to 9V peak to peak
Power-up surge current
1mA
Quiescent current
100μA
Polarity
L1 & L2 are polarity sensitive
Loop powered
Yes
Conventional Manual Call Point WT/LED(yellow)55100-002APO
Humidity (max)
93% RH
Humidity (min)
0% RH
Humidity
0% to 93% (no condensation or icing)
Humidity Note
no condensation or icing
Operating temperature (min)
-10°C
Operating temperature (max)
55°C
Operating temperature
-10 to 55°C
IP rating Value
IP24D
Operating temperature
14 to 131°F
Operating temperature (max)
131°F
Operating temperature (min)
14°F
I.S.Manual Call Point-MEDC Style (GLASS & FLIP LID) 55000-961APO
Protocol voltage (max)
9V
Protocol voltage (min)
5V
Protocol voltage
5 to 9V peak to peak
Quiescent current
300μA
Quiescent current tested at
24V dc
Conventional I.S.Manual Call Point (WithOut LED) 55000-031APO
Colour
Red
Weight
180g
Product length
89mm
Product width
59.2mm
Product depth
93mm
Key type
KAC Manal Call Point test & reset key
Conventional I.S. Manual Call Point-OUTDOOR(WithOut LED) 55100-033APO
Colour
Red
Weight
350g
Product length
97.5mm
Product width
71mm
Product depth
93mm
Key type
KAC Manal Call Point test & reset key
Conventional Manual Call Point -OUTDOOR (WITHOUT LED)55100-003APO
Colour
Red
Weight
350g
Materials housing
Polycarbonate
Product length
110mm
Product width
110mm
Product depth
74mm
Discovery Manual Call Point-OUTDOOR- 58200-950APO
Protocol voltage (max)
9V
Protocol voltage (min)
5V
Protocol voltage
5 to 9V peak to peak
Power-up surge current
1mA
Maximum power-up time
1 second
Quiescent current
100μA
Quiescent current tested at
24V dc
Polarity
L1 & L2 are polarity sensitive
Conventional Open-Area Sounder- RED BODY-29600-322APO
Supply voltage (min)
9V dc
Supply voltage (max)
60V dc
Supply voltage (Vmin-Vmax)
9 to 60V dc
Conventional Open-Area Sounder VID-Red Body-(Red Flash) 29600-323 For use with conventional systems
A choice of 32 tones including all the major international standards
Simple ‘First Fix’ installation
Volume control - typical 8dB
Conventional Open-Area AV Time Saver Base-Shallow 29600-320APO For use with conventional systems
A choice of 32 tones including all the major international standards
Simple ‘First Fix’ installation
Volume control - typical 8dB
Coventional Open-Area AV Time Saver Base-Deep 29600-321APO For use with conventional systems
A choice of 32 tones including all the major international standards
Simple ‘First Fix’ installation
Volume control - typical 8dB
Conventional I.S. Open-Area Sounder VID-Red Body(Red FLash)29600-446APO
Colour
Red
Product length
95mm
Product width
89mm
Product depth
116mm
Weight
350g
Product length
3.74in
Product width
3.5in
Product depth
4.57in
Conventional Fire Bell (6'') 29600-400APO Low current consumption
Universally-recognisable sound
Xpert 7 Base 45681-210APO
Terminal functions L1 in
-L1 in Loop in & out, double terminal
Polarity
L1 & L2 are polarity insensitive
Optical Smoke Detector 55000- 600APO
5 to 9V peak to peak
Protocol voltage (max)
9V
Protocol voltage (min)
5V
Power-up surge current
1mA
Maximum power-up time
4 seconds
Status indicator - Alarm
Red
XP95 Heat Detector (CS) 55000-401APO
Protocol voltage
5 to 9V peak to peak
Protocol voltage (max)
9V
Protocol voltage (min)
5V
Power-up surge current
1mA
Maximum power-up time
4 seconds
XP95 Heat Detector (A2S) 55000-400APO
Protocol voltage
5 to 9V peak to peak
Protocol voltage (max)
9V
Protocol voltage (min)
5V
Power-up surge current
1mA
Maximum power-up time
4 seconds
Isolator Negative 55000-720APO
Storage temperature
-30 to 80°C
Storage temperature (max)
80°C
Storage temperature (min)
-30°C
XP95 Optical Smoke Detector 55000-620APO
Protocol voltage
5 to 9V peak to peak
Protocol voltage (max)
9V
Protocol voltage (min)
5V
Power-up surge current
1mA
Maximum power-up time
4 seconds
XP95 Heat Detector (A2S)
Protocol voltage
5 to 9V peak to peak
Protocol voltage (max)
9V
Protocol voltage (min)
5V
Power-up surge current
1mA
Maximum power-up time
4 seconds
XPERT 7 Base -Isolating Materials terminals
Nickel plated stainless steel
Product depth
24mm
Product diameter
100mm
Product depth
0.94in
Product diameter
3.94in
XP95 Manual Call Point Isolating 55100-908APO
Protocol voltage (max)
9V
Protocol voltage (min)
5V
Protocol voltage
5 to 9V peak to peak
Power-up surge current
1mA
Maximum power-up time
1 second
Open Area Sounder 55000-001APO
Max. sound output tone:
100dB (A)
Supply voltage (Vmin.-Vmax.):
17 to 28V dc
Humidity:
0% to 95% RH (no condensation or icing)
Ingress Protection:
IP65
Operating temperature:
-10 to 55°C
Color:
red
XP95 Open Area Sounder VID-Red Body 55000-005APO
Polarity
L1 & L2 are polarity sensitive
Power-up surge current
1.2mA
Maximum power-up time
<1 second
Quiescent current
330μA
Quiescent current tested at
24V dc
XP95 Open-Area Multi-Tone Sounder Red Body 55000-278APO
Power-up surge current
1.2mA
Maximum power-up time
<1 second
Quiescent current
330μA
Quiescent current tested at
24V dc
Supply voltage (min)
18V dc
Supply voltage (max)
28V dc
Supply voltage (Vmin-Vmax)
18 to 28V dc
Intelligent Switch Monitor Module SA4700-100APO
Protocol voltage (min)
5V
Protocol voltage (max)
13V
Protocol voltage
5 to 13V peak to peak
Quiescent current
500μA
Quiescent current tested at
24V dc
Supply voltage (max)
35V dc
Supply voltage (min)
17V dc
Supply voltage (Vmin-Vmax)
17 to 35V dc
XP95 Zone Monitor Module-Isolating 55000-845 APO
Protocol voltage (min)
5V
Protocol voltage (max)
9V
Protocol voltage
5 to 9V peak to peak
Supply voltage (max)
28V dc
Supply voltage (min)
17V dc
Supply voltage (Vmin-Vmax)
17 to 28V dc
Power-up surge current
3.5mA
Maximum power-up time
150ms
Stabilization time on power up
4s
Intelligent INPUT-OUTPUT Module SA4700-102APO
Protocol voltage (min)
5V
Protocol voltage (max)
13V
Protocol voltage
5 to 13V peak to peak
Quiescent current
500μA
Quiescent current tested at
24V dc
Supply voltage (max)
35V dc
Supply voltage (min)
17V dc
Supply voltage (Vmin-Vmax)
17 to 35V dc
Intelligent INPUT-OUTPUT Module (250V AC) SA4700-103APO
Humidity
0% to 95% (no condensation or icing)
Humidity Note
no condensation or icing
Humidity (max)
95% RH
Humidity (min)
0% RH
Operating temperature
-40 to 70°C
Operating temperature (max)
70°C
Intelligent INPUT/OUTPUT Module (TWIN) SA4700-104APO
Protocol voltage (min)
5V
Protocol voltage (max)
13V
Protocol voltage
5 to 13V peak to peak
Quiescent current
500μA
Quiescent current tested at
24V dc
Supply voltage (max)
35V dc
Supply voltage (min)
17V dc
Supply voltage (Vmin-Vmax)
17 to 35V dc
Intelligent Switch Monitor Module(TWIN) SA6700-100APO
Protocol voltage (min)
5V
Protocol voltage (max)
13V
Protocol voltage
5 to 13V peak to peak
Quiescent current
500μA
Quiescent current tested at
24V dc
Supply voltage (max)
35V dc
XP95 AV Control Module Isolating 55000-852APO
Protocol voltage (min)
5V
Protocol voltage (max)
9V
Protocol voltage
5 to 9V peak to peak
Supply voltage (max)
28V dc
Supply voltage (min)
17V dc
Supply voltage (Vmin-Vmax)
17 to 28V dc
XP95 DIN-Rail Mini Switch Monitor Module Isolating 55000-760APO
Protocol voltage (min)
5V
Protocol voltage (max)
9V
Protocol voltage
5 to 9V peak to peak
Supply voltage (max)
28V dc
Supply voltage (min)
17V dc
Supply voltage (Vmin-Vmax)
17 to 28V dc
Power-up surge current
0.8mA
Quiescent current, 20kΩ EOL fitted
0.2mA
Addressable INPUT/OUTPUT Module 55000-847
Loop voltage: 17-28V DC
Switch on Surge: 3.5 mA
Input monitoring voltage: 9-11V
Continuous current: 1A
IP classification: IP54
Dimensions: 150 x 90 x 48 mm
Finish color: White
Conventional End To End Beam Detector 29600-929 Full icon-based, easy-to-use LCD display on the low level controller for ease of commissioning, testing and maintenance
Aesthetically pleasing to suit modern architectural buildings and heritage sites
Range 5 to 120 metres
Intelligent Reflective Beam Detector Auto Aligning SA7100-100APO
Colour
Grey
Materials housing
Polycarbonate
Controller with base - height
230mm
Controller with base - weight
1000g
Controller with base - width
202mm
Detector with base - height
131mm
Detector with base - weight
537g
Bram Detector BackBox 29600-241
The Beam Detector Backbox allows easy first fixing of the cabling and terminations to the XP95 Reflective Beam Detector. The backbox can be surface or flush mounted.
Conventional Auto Aligning Beam Detector 29650-069
The Conventional Reflective Beam Detector comprises of a ground level controller, detector head with auto-aligning feature, integral laser for rapid initial alignment and single prism. An additional detector head can be added to the controller.
Reflective Beam Detector(ADD-ON) Auto Aligning 29650-070 Supply Voltage: 14-36 V DC
Operating Current: 1 Detector: 6mA; 2 Detectors: 8.5mA
Operating Current: 37mA
Response Threshold: 10-60%
Delays (User settable, default 35%): Alarm: 2-30 Seconds; Fault: 2-30 Seconds
IP Rating: 54
Optical Wave Length: 850nm
Beam Detector Extension Kit (50-100M)29600-526
Extension Kit for the Auto-Aligning Beam Detector.
Beam Detector Bracket 29600-527
Universal Bracket for the Auto-Aligning Beam Detector.
Beam Detector Surface Mouting Plate 29600-528 Surface Mounting Plate for Auto-Aligning Beam Detector.
Beam Detector Prism Plate (4PRISMS) 29600-529
Beam Detector Prism Plate (1PRSM)29600-530
Apollo Xpert Card 38531-771 Simplifies and speeds up installation and commissioning
Uses patented proven technology
Address remains the same, no matter how often detectors are replaced
Flexibility to create any address
XP95 Open Area Multi-Tone Sounder VID Red BOdy (RED FLash)55000-291APO
Power-up surge current
1.2mA
Maximum power-up time
<1 second
Quiescent current
330μA
Quiescent current tested at
24V dc
Supply voltage (max)
28V dc
Supply voltage (min)
18V dc
Supply voltage (Vmin-Vmax)
18 to 28V dc
XP95 Open-Area VID-Red Body(RED FLASH)55000-877APO
Power-up surge current
1mA
Quiescent current
150μA
Quiescent current tested at
24V dc
Supply voltage (max)
28V dc
Supply voltage (min)
17V dc
Supply voltage (Vmin-Vmax)
17 to 28V dc
XP95 Open-Area VID-White Body 55000-878APO
Power-up surge current
1mA
Quiescent current
150μA
Quiescent current tested at
24V dc
Supply voltage (max)
28V dc
Supply voltage (min)
17V dc
Supply voltage (Vmin-Vmax)
17 to 28V dc
Discovery Open-Area Voice Sounder VID -Red Body (Red Flash)-Isolating 58000-030APO Four pre-set message pairs
Capable of up to 15 tone message pairs
Low current and high volume
Fully synchronised
Set up and test at point of installation
Dahua Surveillance Camera & Security Systems
BROCHURE
Hikvision Surveillance Camera & Security Systems
Premium Line Cables
BROCHURE
Zycoo IP Pabx
BROCHURE
TOA PA Systems
KDK PRODUCTS
BROCHURE
Distribution Transformer
BROCHURE